|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Clinical Nephrology |
,
,
,
,¶
Departments of * Radiology,
Cardiology, and || Nephrology, Texas Heart Institute at St. Lukes Episcopal Hospital, Houston, Texas;
Philips Medical Systems, Cleveland, Ohio; and Departments of ¶ Medicine and
Radiology, Baylor College of Medicine, Houston, Texas
Address correspondence to: Dr. Scott D. Flamm, Cardiovascular Imaging, Cardiovascular Imaging Laboratory, Department of Radiology, Hb6, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195. Phone: 216-444-2740; Fax: 216-636-0822; E-mail: flamms{at}ccf.org
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
A number of investigators have reported reference values for renal length (712) and, to a lesser extent, renal volume in healthy adults (7,8), as measured by ultrasonography. The ultrasonography method that is used to measure kidney volumes is two-dimensional in nature, is subject to operator dependence, and uses geometric assumptions about the shape of the kidney to estimate kidney volumes. In contrast, tomographic imaging methods such as x-ray computed tomography (CT) and magnetic resonance imaging (MRI) can acquire three-dimensional data and, therefore, do not rely on geometric assumptions to estimate organ volumes. In the case of CT, the need for ionizing radiation and potentially nephrotoxic contrast media limits its place as a routine noninvasive imaging method for measuring kidney volumes. Conversely, MRI has the benefit of acquiring true tomographic data along any orientation, without the constraints of ionizing radiation and nephrotoxic contrast burden. Nevertheless, the literature contains few reports of renal dimensions as determined by MRI (8). The purpose of this work was to establish reference values for renal length and volume using MRI in patients with no clinical history of renal disease.
| Materials and Methods |
|---|
|
|
|---|
|
After contrast administration (0.2 mmol/kg Gd-chelate), 20 to 24 transverse slices (7-mm thickness and 1-mm gap) that covered the entire length of the kidney in craniocaudal direction were acquired using a T1-weighted gradient echo sequence. The specific acquisition parameters were as follows: Repetition time (msec)/echo time (msec), 315/6.3; flip angle, 80 degrees; field of view, 30 to 36 cm, depending on the patients body habitus; sensitivity encoding factor of 2; breath-hold duration, 16 s; acquired voxel size, 1.9 x 2.1 x 7 mm; and reconstructed voxel size, 1.6 x 1.6 x 7 mm (after zero padding). The paramagnetic gadolinium contrast agent ensured enhancement of the renal parenchyma and facilitated volume determination; a fat saturation pulse was used to suppress the signal from surrounding perirenal adipose tissue and improve delineation of the renal border.
Phantom Study
To evaluate the accuracy of MR for assessing renal volumes in vivo, we performed the following phantom study. Five freshly excised porcine kidneys were obtained from a local market. All surrounding tissues were removed to the extent possible without damaging the integrity of the kidney.
MRI Acquisition
All imaging was performed on the same 1.5-tesla MR scanner that was used for patient studies. A quadrature head coil was used for signal reception. The excised kidneys were placed in the MR scanner and were imaged with four different imaging techniques of progressively increasing acquired spatial resolution (A: 1.9 x 2.1 x 7 mm3; B: 2 x 2 x 4 mm3; C: 2 x 2 x 2 mm3; and D: 1 x 1 x 1 mm3). Technique A had acquisition parameters and spatial resolution identical to that used in the clinical studies described above. Techniques B, C, and D had progressively higher spatial resolutions and required scan times of 21, 47, and 189 s, respectively.
To assess the effect of the orientation of the kidneys with respect to the imaging plane on volumetric measurements, we performed the following experiment. The transverse imaging volume was angulated with respect to the kidney by adjusting the orientation of spatial encoding gradients. The imaging plane of the ex vivo kidneys was rotated about the right-to-left axis and the anterior-posterior axis, at various angulations from 0 to 40 degrees. This resulted in a total of 84 imaging volumes of the kidneys (four resolutions with nine angulations for one kidney, and four resolutions and three angulations for four kidneys).
Water Displacement Method
The water displacement method was used to obtain an independent determination of the kidney volume. The kidneys were immersed in 0.9% saline, and the displaced solution was measured using a graduated cylinder to determine the kidney volume. The measurements were repeated six times, and the mean and SD of the six repeated measurements were calculated (total of 30 measurements). MRI and determination of porcine kidney volume using the water displacement method were completed within 2 h of each other.
Data Analysis
Both the patient data and the phantom data were transferred to a commercially available postprocessing workstation (EasyVision, release 5.0; Philips Medical Systems) for analysis. On the transverse T1-weighted gradient echo images, an experienced cardiovascular imager (B.C.) traced the contour of the kidneys. The renal pelvis and vasculature were excluded from the area measurements (Figure 1). The areas that were circumscribed by the manual contour on each slice were summed for each kidney by multiplying the number of pixels within the contour and the area per pixel. Then, multiplying the total area by the slice thickness (0.8 cm), the kidney volume was computed (i.e., the disc-summation or the voxel-count method) for all 150 patients. To determine the length of each kidney, we found the true long axis by reorienting the transverse slices using multiplanar reformations that were angled obliquely along the coronal and sagittal axes of each kidney. In general, the length of the long axis was measured along the craniocaudal direction of each kidney, but occasionally it was measured in the oblique anteroposterior axis for more horizontally oriented kidneys.
|
/6 x (length x width x depth), with the width and depth measured at the renal hilum (8,13,14).
Statistical Analyses
All data are presented as mean ± SD. Statistical differences were assessed with the two-sample t test when variables were continuous or with the
2 test for nominal data, using a cutoff value of P < 0.05 to indicate significance. Correlations between variables were calculated with the Pearson correlation coefficient. All statistical analyses were performed using a commercially available analysis package.
| Results |
|---|
|
|
|---|
|
|
|
|
The kidney volumes that were calculated by the ellipsoid formula were significantly smaller in both genders (P < 0.0001; Table 4) when they were compared with the MRI disc-summation method. The mean kidney volume was approximately 18% less by the ellipsoid method in men and 15% less in women.
For clarification of a potential decline in kidney volume with age, the patients were divided empirically into three age groups:
40 yr, 41 to 60 yr, and >60 yr. Finer gradations (e.g., by decade) were not made because of the relatively small number of patients within each gender. For men, the right and left renal volumes for the three groups were as follows: 219 ± 38 and 213 ± 41, 212 ± 37 and 217 ± 37, and 190 ± 29 and 192 ± 26 ml, respectively. For women, the right and left renal volumes for the three groups were as follows: 167 ± 41 and 166 ± 39, 152 ± 27 and 160 ± 37, and 147 ± 30 and 148 ± 28 ml, respectively (Figure 3). In both men and women, renal volumes tended to decline with age; however, this trend did not reach statistical significance except between the groups of 41 to 60 yr and >60 yr in men (P < 0.02). The findings were similar when the kidney volumes were indexed to BSA.
|
| Discussion |
|---|
|
|
|---|
The results from our phantom study highlight several important factors. First, the MRI estimates of kidney volumes were within 5% of the volume as determined using the water displacement method, corroborating that tomographic images of the kidneys that were acquired using MRI indeed can provide reliable and consistent determinations of kidney volume without the geometric assumption limitations that are inherent in the ellipsoid method. Use of the ellipsoid formula for volume calculation underestimated the true volume of the ex vivo kidneys by 21 to 29%. There is consistent, although only slight, underestimation of kidney volume as determined by the MRI disc-summation method compared with the water displacement method. This underestimation may be attributed partly to the presence of extraparenchymal tissues that were not completely removed to avoid damaging the renal integrity.
Second, the changes in the acquired spatial resolution of the imaging techniques from a coarse spatial resolution (a voxel volume of 28 mm3) to a fine spatial resolution (a voxel volume of 1.0 mm3) did not have an appreciable effect on the mean kidney volume measured. This suggests that the spatial resolution that was used in routine patient studies (28 mm3 voxel volume) is sufficient to measure the kidney volumes accurately, and the partial volume effect at this level of spatial resolution does not introduce significant errors in volume calculations.
Third, the relative orientation of the kidney with respect to the imaging volume also did not have an adverse effect in the measurement of kidney volumes. Independent of the spatial resolution of the MRI method (1, 8, 16, or 28 mm3) or the orientations of the imaging volume with respect to the ex vivo kidney specimen, the volume estimates were within 5% of the true kidney volume. Therefore, the variations in anatomic orientation of the kidney in vivo seem to have little effect on the volumetric measurements. Predictably, the SD of the high spatial resolution imaging technique (1 mm3) was the smallest among the four techniques used (Table 2), reflecting the immunity of high spatial resolution acquisition to the relative orientation between the object and the imaging volume. Even at the coarsest spatial resolution acquisition (28 mm3 voxels), the SD (5.4 ml) of volume in kidney B remained <5% of the mean.
The results from our patient study suggest the following. First, our work demonstrates that kidney lengths and volumes by MRI disc summation (men 12.4 ± 0.9 cm for length and 202 ± 36 ml for volume; women 11.6 ± 1.1 cm for length and 154 ± 33 ml for volume) are consistently larger than reported. Specifically, the current literature reference values, principally from ultrasonography measurements, suggest that a normal adult kidney is approximately 11 ± 1.0 cm long (712), with a normal volume of 110 to 190 ml in men and 90 to 150 ml in women (16). An important caution is that these reference values are based on ultrasonography data where calculations are derived from the ellipsoid formula, which has the previously noted inherent geometric assumption limitations. Furthermore, accurate measurement of the length, width, and depth of the kidney using ultrasonography may be hampered by limited acoustic windows from overlying bowel gas, other soft tissue structures, or patient body habitus. In addition, the double oblique orientation of the kidney requires the ultrasonography operator to make subjective decisions to measure the true length of the kidneys, values that then are incorporated into volumetric calculations. Indeed, Bakker et al. (14), using a pig model, noted the ellipsoid method underestimated kidney volume by 9 to 24%, and in their group of 20 healthy volunteers noted a 24% underestimation of ultrasonography ellipsoid formuladerived kidney volumes compared with the MRI disc summationdetermined volumes (Table 5). In contrast, Coulam et al. (17), also using a pig model, noted that kidney volume as measured by MRI correlated well with that obtained by water displacement (R2 = 0.86), with MRI-based kidney volume underestimating true kidney volume by only 5 to 8%. The ex vivo kidney volume calculations from this MR study also are in agreement with previous reports regarding renal volume measurements (18).
|
Third, in contrast to previous reports, the results from our study do not suggest any significant difference between the left and right kidney volumes of either gender (7,10). A study by Emamian et al. (7) of 665 adult volunteers who were examined by ultrasonography found that kidney volume correlated with BSA in both genders. Furthermore, by indexing the volume to BSA, the gender differences between renal volume were eliminated. In contrast, our study reveals only a modest correlation (r = 0.5) between kidney volume and BSA in men and no correlation with BMI, height, or weight. Our data suggest that the range of normal reference values (mean ± 2 SD) for male and female kidney lengths when using MRI is 10.7 to 14.3 and 9.5 to 13.9 cm, respectively; the range of normal reference values (mean ± 2 SD) for male and female kidney volumes is 132 to 276 and 87 to 223 ml, respectively (Table 5).
In addition, it seems that there is a trend for modest decline in renal volume with age (Figure 3), although the trend did not reach statistical significance except between men in the 41- to 60-yr and the >60-yr groups. Greater numbers of patients may be necessary to determine whether a true decline in kidney volume occurs with age.
MRI may be uniquely suited for noninvasive evaluation of renal pathology. Although CT also can provide noninvasive determination of kidney size and volume, the technique entails substantial ionizing radiation and potentially nephrotoxic contrast agent administration that limits its use as a method of choice for routine noninvasive evaluation, particularly in patients with potential renal pathology. Moreover, MRI provides a breadth of information in a single examination that can benefit patient management. For example, in addition to renal morphology and tissue characterization, MRI delineates renal vascular morphology from three-dimensional contrast-enhanced MRA (19), further defines the hemodynamic significance of renal artery stenoses from signal dephasing in phase-contrast MRA (6,20), and can reveal quantitative information regarding the amount and the pattern of blood flow through renal arteries (21). Accurate kidney volumes and lengths provide additional valuable information to the clinician in determining renal status, as well as in monitoring response to treatment. Our ex vivo phantom study confirms that MRI estimation of renal volumes is not hampered either by the relatively modest spatial resolution of the MRI techniques used in routine clinical practice or by the natural variation in orientation of the kidneys with respect to the orthogonal planes of the body.
Study Limitations
The patients in this study were identified retrospectively from our MRI database. Hospital records were reviewed carefully to ensure that the participants had no intrinsic renal disease. Specifically, the GFR of each patient was calculated using the MDRD formula, and the results were within the mean ± 2 SD of the reference ranges for GFR by age and gender as proposed by Manjunath et al. (15). It is possible that our patients had subclinical renal disease, because more than half were hypertensive; approximately 25% of patients had diabetes; and the mean BMI (29 and 28 kg/m2 in men and women, respectively) indicates that our patient group is overweight bordering on obesity. Nonetheless, despite these potentially adverse influences, our measured kidney lengths and volumes still were considerably larger than current reference standards as obtained by ultrasonography.
Our sample size is modest because we included in our database only patients who had normal renal function and did not meet any exclusion criteria. We are currently collecting data prospectively and anticipate having results from a larger population over varying age ranges.
Recent reports have suggested that gadolinium-based contrast agents may lead to acute renal failure in patients with advanced renal disease (22,23). We also routinely obtain images through the abdomen with steady-state free-precession gradient echo and fat-saturated T2-weighted spin echo sequences before gadolinium administration. High contrast between the renal parenchyma and the surrounding tissues is obtained similar to that for postgadolinium imaging sequences. Renal volume as calculated from the aforementioned sequences and the postgadolinium sequences should be comparable; however, direct comparison was not made in this study.
| Conclusion |
|---|
|
|
|---|
20%. The length and the volume of kidneys as obtained by MRI in patients with no known history of intrinsic renal disease are greater than the commonly quoted reference values that are based on ultrasonography measurements: By MRI, the range of normal reference values (mean ± 2 SD) for male and female kidney lengths is 10.7 to 14.3 and 9.5 to 13.9 cm, respectively; for male and female kidney volumes, the normal reference values (mean ± 2 SD) are 132 to 276 and 87 to 223 ml, respectively. Larger, prospective studies may provide further incremental refinements in these reference values. The current clinical practice of using traditional ultrasonography-based kidney dimensions can be improved on by the disc-summation technique via MRI, providing more accurate data for clinical decision- making. | Disclosures |
|---|
|
|
|---|
| Acknowledgments |
|---|
| Footnotes |
|---|
Received March 17, 2006. Accepted September 28, 2006.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
A. A. Sanusi, F. A. Arogundade, O. C. Famurewa, A. O. Akintomide, F. O. Soyinka, O. E. Ojo, and A. Akinsola Relationship of ultrasonographically determined kidney volume with measured GFR, calculated creatinine clearance and other parameters in chronic kidney disease (CKD) Nephrol. Dial. Transplant., May 1, 2009; 24(5): 1690 - 1694. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. C. Kim, D. M. Yang, S. H. Lee, and Y. D. Cho Usefulness of Renal Volume Measurements Obtained by a 3-Dimensional Sonographic Transducer With Matrix Electronic Arrays J. Ultrasound Med., December 1, 2008; 27(12): 1673 - 1681. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Grantham Autosomal Dominant Polycystic Kidney Disease N. Engl. J. Med., October 2, 2008; 359(14): 1477 - 1485. [Full Text] [PDF] |
||||
![]() |
P.-H. Vivier, M. Dolores, I. Gardin, P. Zhang, C. Petitjean, and J.-N. Dacher In Vitro Assessment of a 3D Segmentation Algorithm Based on the Belief Functions Theory in Calculating Renal Volumes by MRI Am. J. Roentgenol., September 1, 2008; 191(3): W127 - W134. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. B. Douverny, J. C. Baptista-Silva, J. O. M. Pestana, and R. Sesso Importance of renal mass on graft function outcome after 12 months of living donor kidney transplantation Nephrol. Dial. Transplant., December 1, 2007; 22(12): 3646 - 3651. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |